--- Generator Specifications ---
Rated Continous Output - Kva 2.12
Maximum Output - Kva 2.49
Phases 1
Output Volts 230V
Rated power factor 0.9 PF
Frequency 50 Hz
Battery charger voltage N / A
Battery charger current N / A
Panel location On Alternator
Frame type Tubular
Compliancy certification CE
--- Alternator Specifications ---
Alternator manufacturer NSM
Model ES 80 B
Poles 2
Revolution speed 3000 rpm
Voltage 230V
Frequency 50 Hz
Efficiency at 75% load 70 %
Voltage regulation system Capacitor

--- Aditional Information ---
Skid mounting No
Fuel tank location On Engine
Fuel tank capacity 3.6 Litres
Automatic supplement tank No
Running time at 75% COP 4.34 hours
Noise level at 7 meters 68.2 dBA
Acoustic power at 4 meters 93.2 dBA
Guaranteed noise level 94 dBA
Operating conditions -15 ~ +40 °C
--- Engine Specifications ---
Engine Make Honda 4 Stroke
Engine Model GX160
Fuel Type LPG
No of cylinders & disposition 1, inclination angle
Displacement 163 cm³
Air intake Natural
Starting system Recoil
Nominal operating speed 3000 rpm
Speed governor Mechanical
Continuous power COP 2.5 kW
Prime power PRP 2.8 kW
Standby power LTP 3.2 kW
Lube oil capacity 0.61
Fuel consumption at 75% load 0.83 Litres per hour
Electric circuit voltage N / A

--- Dimentions and weight---
Dimentions (L, W, H) mm 640 x 458 x 400
Dry weight 38 kg